Showing posts with label wiring. Show all posts
Showing posts with label wiring. Show all posts

Wiring diagram 06 chev trailblazer

This vehicle will not crank over with the key. But will start when i put power to the ignition side of the starter. I checked the start fuse it is good.It has power to the start fuse when the key is in crank position.I Changed the start relay with a known good relay.

2006 Trailblazer 4.2 2006 Envoy 4.2
Customer Concern:
No crank, the starter will not engage when the key is turned to the start position.
Average Reported Mileage:
77912
Tests/Procedures:
1. With the key in the run and start position check for Battery Voltage (B+) at fuse #22 in the under hood fuse block.

2. If there is less than B+ at #22 fuse check for B+ with the key in the run and start position at connector C201 at the steering column harness to the I/P harness, at the base of the steering column pin C6 Pink wire.

3. If there is less than B+ at pin C6, check for B+ at pin D2 Red wire of the same connector.

4. If there is B+ at pin D2 but not at pin C6, replace the ignition switch.

Identifix shows 5 confirmed fixes for this problem, replacing the ignition switch.